ACCESSORIES
ADVANCED SERIES
GENERAL
ONE-PAGE FLYERS
ORGINAL SERIES
SANIFLO SERIES
HIGH PRESSURE PUMP
Support
My status
Skype 1
>> ACCESSORIES

FCSII_SPCI

Fcsii Spci

Enclosure: Nema 4X, ABS case with clear polycarbonate

cover and stainless steel screws.

Cable Grip: Polyamide (nylon) with Buna seal, “liquid

tight,” 10.15 mm (0.4") cable capacity.

Keypad: Polyester membrane type. Splash proof

with tactile interface.

Power Requirements: 110-120V AC 50/60 Hz.,

220-230V AC 50/60 Hz., 15 watts.

Pump Output Voltage and Amps: 12V DC .750

amps. Recommended Solenoid coil DC resistance

nominal 16 Ohms.

Contact Requirements for External Input Activation:

Dry contact rated at 1 mA or greater.

Wil-Gard Input: Dry contact rated at 1 mA or

greater.

External Output: Relay contacts. The ratings are

100v DC at 0.5 amps, maximum.

Power Cord: U.S.-style non-grounding cord,

1.83m (6') UL/CSA listed.

Solenoid Cord: 18 ga. stranded zip cord,

2.44m (8').

Operating Temperature:

0°C (32°F) to 50°C (122°F).

Storage Temperature:

–10°C (14°F) to 60°C (140°F).

Fuse: Internally resettable (non-replaceable).

Hold = .65 Amps, Trip = 1.3 Amps, UL, CSA &

TUV recognized.

RECOMMENDED WIRE GAUGE:

Power Input Wire: 18 AWG minimum/max

distance 100’.

Wire to Solenoid Pump: 18 AWG minimum/max

distance 150’.

Wil-Gard Input Wire: 24 AWG minimum/max

distance 1000

OTHER PRODUCTS
Wg
Surge Dampeners
Jaws
Bf
Air Tech
DAI NAM TRADING AND CONSTRUCTION COMPANY
Address: No.300, 1st National, Trung dung, Bien Hoa City, Dong Nai Province
Phone: +84-251 3824588 - 3810572 - 3824988
Fax: +84-251 3825319
Email: danaco@wildenpumps.com.vn
Online: 2
Hit counter: 169027
Copyright © 2024 Danaco
All rights reserved. Designed & Developed by EMSVN